10kV Side Mounted Circuit Breaker IEC60420 Standard Modular Design For Ring Main Unit

Product Details:

Place of Origin: China
Brand Name: Dong Sheng Yuan
Model Number: 10kV side-mounted circuit breaker (for XGN15-12 ring main unit)

Payment & Shipping Terms:

Minimum Order Quantity: 1
Price: $662
Packaging Details: Wooden pallet/Boxed
Delivery Time: T+30
Payment Terms: TT
Get Best Price Chat Now

Detail Information

Rated Voltage: 12/24KV Rated Current Reaching: 630A
Standard: IEC60420 Altitude: ≤1000m
Earthquake Intensity: ≤magnitude 8.
Highlight:

10kV Side Mounted Circuit Breaker

,

Modular Design Side Mounted Circuit Breaker

,

IEC60420 Side Mounted Circuit Breaker

Product Description

10kV Side-Mounted Circuit Breaker (for XGN15-12 Ring Main Unit)
XGN15-12~24 Ring Main Unit
Rating: Rated voltage 12/24KV, rated current reaching 630A.
Application: Mainly applicable in urban power grid features and renovation projects, industrial and mining enterprises, high-rise buildings, and communal facilities. For power distribution, controlling, and protection of electric equipment as the loop power supply unit or terminal equipment. It can also be installed in a pre-loaded substation.
Medium Voltage Switchgear
XGN15-12~24 Air-insulated RMU (Fixed Type)
Rating: Rated voltage 12/24KV, rated current reaches 630A.
Application: Mainly applicable in urban power grid features and renovation projects, industrial and mining enterprises, high-rise buildings, and communal facilities. For power distribution, controlling, and protection of electric equipment as the loop power supply unit or terminal equipment. It can also be installed in a pre-loaded substation.
Feature: Use the SF6 load switch and the load switch-fuse combination as the main switch. Equipped with a vacuum load switch and spring spring-operating mechanism that can be operated by hand or electrically. Grounding switch and insulating switch are equipped with hand-operating mechanisms, with a small volume and high security.
Standard: IEC60420
Operating Conditions
  • Ambient air temperature: -15℃ ~ +40℃. Daily average temperature: ≤35℃.
  • Altitude: ≤1000m.
  • Relative humidity: Daily average ≤95%, daily average of vapour pressure ≤2.2kpa. Monthly average ≤90%, monthly average of vapour pressure ≤1.8kpa.
  • Earthquake intensity: ≤magnitude 8.
  • Applicable in places without corrosive and flammable gases.
Note: Customized products are available.
Features
  • Modular design, where each unit module can be combined and expanded arbitrarily, facilitating flexible system configurations and wide adaptability.
  • The cabinet adopts an armored structure with metal partitions between compartments.
  • The operating mechanism adopts corrosion-resistant metals, and the rotating parts are designed with self-lubricating bearings, ensuring unaffected performance in various environments and eliminating the need for regular maintenance.
  • To accommodate power grid automation and improve distribution reliability, it can be equipped with motorized mechanisms, distribution network control terminal units, and possess telecontrol functions.
  • The compact design of the cabinet incorporates a three-position rotary load switch, effectively reducing the number of components and enabling mechanical interlocking for five protection measures.
  • The primary circuit simulation single-line diagram and analog display can demonstrate the internal status of the switch, enabling easy, accurate, and safe operation.
Technical Data
Rated voltageUnit12KV24KV
Item/Load switch cabinetCombined electrical cabinetCircuit breaker cabinet20KVSF6 Ring switch equipment
Rated frequencyHZ50/6050/6050/6050/60
Rated currentA/   
Main busbarA630630630630
Branch busbarA630125①630630/≤100②
Rated insulation levelKV/   
Power frequency withstand voltagePhase-to-phase and phase-to-groundKV42424265
Gap between breaksKV484848/
Break control and auxiliary circuitKV222/
Lightning impulse withstand voltagePhase-to-phase and phase-to-groundKV75757585
Gap between breaksKV858585/
Rated short-time withstand currentKA/   
Main circuitKA20/3s-25/2s/
Grounding circuitKA20/25-25/2s/
Rated peak withstand currentKA50-63/
Rated short-circuit making currentKA50806350
Rated short-circuit breaking currentKA-31.52531.5
Rated transfer currentA-1750-870
Rated active load breaking currentA630--630
Rated closed-loop breaking currentA630-630/
Rated cable charging breaking cableA10-1525
Protection degree/IP3XIP3XIP3X/
Mechanical lifeLoad switchtimes50005000100003000
Grounding switchtimes2000200020002000
Notes: ① up to the fuse rated current
② ≤100(Load switch-Fuse combination cabinet)
Structure
  • Busbar room: The busbar room is arranged at the upper part of the cabinet. In the busbar room, the main busbar is connected and runs through the entire row of switchgear.
  • Load switch: There is a three-position load switch installed in the switch room. The shell of the load switch is made of epoxy resin cast columns, and filled with sulfur hexafluoride (SF6) gas as the insulation medium. SF6 gas density meters or gas density meters with alarm contacts can be installed in the switch room according to customer requirements.
  • Cable room: The load switch has a spacious cable room, mainly used for cable connections. With sufficient space also to install lightning arresters, current transformers, lower grounding switches, and other components.
  • Operating mechanism, interlock mechanism, and low-voltage control room: The low-voltage room with interlocking functions as a control panel. Spring operating mechanism and mechanical interlocking device with a position indicator installed in a low-voltage room. The low-voltage room can also be equipped with auxiliary contacts, trip coils, emergency trip mechanisms, capacitive live displays, keylocks, and electric operating devices. The low-voltage room space can also be used to install control circuits, metering instruments, and protective relays. The 750mm wide cabinet has two identical low-voltage chambers, which can hold more accessories.
The whole XGN15 switchgear can be divided into upper and lower parts. The upper part of the cabinet includes a busbar room, a load switch, an operating mechanism, and a low-voltage room, which is separated from the lower part of the cabinet. Therefore, it is safer and easier to repair and modify the equipment installed in the upper unit, and to replace the whole upper unit.
Ordering Information
  • Main circuit diagram, busbar diagram for main circuit, allocation diagram.
  • Switchgear outline size.
  • Spare parts and their quantity.
  • Customized products are available per your requirements.

Want to Know more details about this product
I am interested in 10kV Side Mounted Circuit Breaker IEC60420 Standard Modular Design For Ring Main Unit could you send me more details such as type, size, quantity, material, etc.
Thanks!