24KV SF6 RMU Electrical Panel Gis Gas Insulated Switchgear

Certification
China Knkong Electric Co.,Ltd certification
China Knkong Electric Co.,Ltd certification
I'm Online Chat Now

24KV SF6 RMU Electrical Panel Gis Gas Insulated Switchgear

24KV SF6 RMU Electrical Panel Gis Gas Insulated Switchgear
24KV SF6 RMU Electrical Panel Gis Gas Insulated Switchgear

Large Image :  24KV SF6 RMU Electrical Panel Gis Gas Insulated Switchgear

Product Details:
Place of Origin: China
Brand Name: KNKONG
Certification: CB,ISO
Model Number: HXGN15
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: USD 6000-15000
Delivery Time: 12
Supply Ability: 50 units/Month

24KV SF6 RMU Electrical Panel Gis Gas Insulated Switchgear

Description
Standards: IEC 62271-1, IEC 62271-200, IEC 62271- 100, IEC 62271-102. IEC 60282-1, IEC 61243-5, IEC 60529, IEC 61869-1, 2, 3 Voltage: 24KV
Name: Gis Gas Insulated Switchgear Type: SF6 RMU Electrical Panel
Current: 630,1250A Feature: Metal-Clad Enclosed
High Light:

Gis Gas Insulated Switchgear

,

SF6 RMU Electrical Panel

,

24KV Gis Gas Insulated Switchgear

24KV SF6 RMU Electrical Panel Gis Gas Insulated Switchgear

SF6 ring main unit switchgear 11kv Ring Main Unit

Indoor switchgear
SF6 Metal-Clad Enclosed Ring Main Unit
12 24 36KV 50/60Hz, 630,1250A
OEM & ODM,Complete equipment
Meet IEC standards
Send us your SLD (Single Line Drawing) or requirements ,we design switchgear plan for you
Inquire

Product Introduction

General

HXGN15 series unit type SF6 ring net cabinet with SF6 load switch as main switch, for whole cabinet is suitable for electric distribution automation and compact also expandable metal close switchgear. It characters in its simple structure, flexible operation, reliable interlocking and convenient installation etc., which can provide the satisfactory technical projects both for different application occasions and users. With the adoption of sensor technology and the protection relay up to date, plus the advanced technology and flexible assembly project, HXGN15 unit type SF6 ring net cabinet can completely meet the requirement of continuously variable market. It can take self-produced FLBS36 SF6 load break switch ; also according to user’s demand can be assembled with the internationally top-ranking VB4 series vacuum circuit breaker with permanent magnetic mechanism made by AREVA or HD4 type SF6 circuit breaker made by AREVA or HD4 type SF6 circuit breaker made by ABB or with our VS1-12 type vacuum circuit breaker with permanent magnetic mechanism. Operational methods for the main switch inside ring main unit can be either manual or electric power driven. And It can meet the requirement of Four Controls” when matched with FTU and RTU.

 

Feature
1. Metal-clad and fully enclosed structure, can prevent dirt and small animals from entrance.
2. Through the observation windows in the door panel, switch position and general condition can be clearly viewed.
3. The door and switch operating handle are mechanically interlocked to ensure the door cannot be opened with the switch closed and the switch cannot be closed with the door open.
4. The switchgear use vacuum switches combined with solid insulation material. This environmentally-friendly technology avoid the uses of SF6 as an insulation gas.
5. Reliable FIVE-PREVENTION interlock can effectively prevent from mal-operation.

 

Service Environment
1. Air temperature: -35℃~+40℃
2. Humidity: Monthly average humidity 95%; Daily average humidity 90% .
3. Altitude2500m
4. Ambient air not apparently polluted by corrosive and flammable gas, vapor etc.
5. No frequent violent shake

 

Technical Date

No. Item Unit Parameter
1 Rated voltage kV 12 24 36
2 Rated frequency Hz 50/60
3 Rated current A 630(1250*)
4

1min Power frequency

withstand voltage

wet kV 38 50 70
dry kV 48 60 85
5 Lightning impulse withstand voltage kV 75 125/150 170
6 Rated short circuit breaking current (peak) kA 80 63 63
7 Rated active load and close circuit breaking current A 63 50 50
8 Rated transferring current A 1700 1200 1200
9 Rated short circuit making current (peak) kA 80 63 63
10 Rated cable(line) charging breaking current A

50 and 10

50/10

11 Cable charge breaking current in earthing fault A 20 20 20
12 Rated withstand current (peak) kA 80 63 63
13 Short time withstand current (2s) kA 25 20 20
14 Mechanism life times 5000 2000 2000

Note: For short circuit breaking and peak current is based on Fuse plus combination