Outdoor Solar Overhead Fault Indicator For MV Power Distribution Network

Certification
China Knkong Electric Co.,Ltd certification
China Knkong Electric Co.,Ltd certification
I'm Online Chat Now

Outdoor Solar Overhead Fault Indicator For MV Power Distribution Network

Outdoor Solar Overhead Fault Indicator For MV Power Distribution Network
Outdoor Solar Overhead Fault Indicator For MV Power Distribution Network Outdoor Solar Overhead Fault Indicator For MV Power Distribution Network Outdoor Solar Overhead Fault Indicator For MV Power Distribution Network

Large Image :  Outdoor Solar Overhead Fault Indicator For MV Power Distribution Network

Product Details:
Place of Origin: China
Brand Name: Knkong
Certification: ISO IEC CB
Model Number: DYX-KK type fault indicator
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: USD 1000-3000
Packaging Details: Standard export packaging
Delivery Time: 15 working days
Payment Terms: L/C, T/T
Supply Ability: 100 Unit per month

Outdoor Solar Overhead Fault Indicator For MV Power Distribution Network

Description
Type: DYX-KK Name: Fault Indicator
Original: China User: Power Grid
OEM: Yes Manufactory: KNKONG
High Light:

Solar Overhead Fault Indicator

,

Outdoor Overhead Fault Indicator

,

IEC overhead line fault indicator

Outdoor Solar Overhead Fault Indicator For MV Power Distribution Network

 

Product Introduction

 

The ring network cabinet online monitoring equipment is mainly suitable for the automation transformation of the traditional ring network cabinet and the switchgear. While realizing two remote (remote signaling, telemetry) functions, detect and locate the position of short circuit and ground fault at the same time, shorten the power outage time and scope. Not only is important for improving the reliability of power supply, but also an indispensable technology for building an intelligent grid.

 

Advantages

Sampling the zero-sequence current synthesis algorithm, canceling the traditional zero-sequence transformer design, synthesizing the zero-sequence current by detecting the phase sequence to identify the single-phase ground fault, and effectively solving the situation where it is not convenient to install the zero-sequence transformer;
5A self-powered, the acquisition unit uses high magnetic permeability material CT, combined with low-power system design, to ensure that the primary current 5A achieve battery-free full-function operation, improve reliability;
Instead of using the traditional one-time battery power supply scheme, the three-level power architecture of CT power supply, supercapacitors, and non-rechargeable lithium batteries is adopted to guarantee the reliable operation of the equipment;
Electronic current transformer for current and ground electric field detection, It has great linearity of test data and is not affected by wire diameter, thus guarantee test accuracy;
Collection unit indicates failures locally and centrally, eliminating the need to install display panels in every interval;
The energy opening CT is made of anti-rust and anti-corrosion materials, supplemented by a high-level cutting process to ensure that the outdoor environment provides sufficient power for the equipment;
Both the collection unit and the acquisition unit can be controlled remotely and wirelessly.

 

Technical Parameter

Item Parameter

 

Applications

Voltage 6~35kV
Neutral grounding method Various grounding methods are available
Wiring type Overhead insulation and bare wires 35mm²~300mm²

 

Collection unit power supply

Main power PT/CT
Backup power

Rechargeable battery: Lithium iron phosphate or lead-acid colloid battery is dependent on necessary.

All hardware design is compatible for them both.

 

Acquisition unit power supply

Main power Line self-powered (5A full-function operation)
Backup power Disposable lithium battery 3.6V, 8.5Ah
Time of duration of the supercapacitor battery> 12 hours
Static power dissipation Acquisition unit ≤40uA
Collection unit ≤0.2VA
Telemetry accuracy Current

0~200A,measurement accuracy:±2A

200A~600A,measurement accuracy:±1%

Sampling frequency 4096Hz
Fault detection Recognizable fault type Short circuit between phases, various single-phase grounding
Instantaneous faults and permanent faults
Recognition minimum recognition time 0.2s

 

Line status indication

Indication Bright LED
Flashing time after an outage >2000h
Fault reset method Timed automatic reset can be set from 1 to 48 hours
Power-on automatic reset and remote manual reset

 

Local communication

Frequency band 430~480MHz
Communication medium Plastic optical fiber
Communication distance >20m
Mechanical properties Weight <2kg
Protection level Acquisition unit IPX7;Collection unit IPX5
Working environment Temperature -40℃~70℃ 10%~
Humidity 100%
Service life Operating >8 years
Failure-free time (average)

MTBF≥70000h

 

 