Product Details:
|
| Voltage: | 12KV 24KV | Current: | 630A 1250A 1600A 2000A |
|---|---|---|---|
| Breaking Current: | 25KA | Type: | Fixed Type |
| Standard: | GB,IEC,ISO | Manufactory: | KNKONG-ELECTRIC |
| Highlight: | 1250A Indoor Circuit Breaker,25KA Indoor Circuit Breaker,Embedded Pole 12KV Circuit Breaker |
||
VS1-12KV 1250A indoor VCB 25KA with embedded pole
Voltage: 12KV 24KV
Current: 630A 1250A 2000A
Breaking current: 20KA
Type: Fixed
Product overview
The VS1-12 series embedded vacuum circuit breaker produced by KNKONG-ELECTRIC is used for 12kV, 24KV three-phase AC 50Hz/60Hz indoor switchgear, it is the best protection and control unit for industrial and mining enterprises and substation equipment. The spring operating mechanism of the circuit breaker is a modular independent frame design, which is often used in KYN28-12 (24) fixed switchgear. These circuit breakers can be either fixed installation or can be used with a trolley when using the withdrawable version.
Technical Parameters
| No. | Item | Unit | Parameter | ||||||
| 1 | Rated voltage | KV | 12 | ||||||
| 2 | Rated frequency | Hz | 50/60 | ||||||
| 3 | | 1min power frequency withstand voltage(r. m. s) |
KV | 42(phase-to-phase, phase-to-earth) | |||||
| Lighting impulse withstand voltage (peak) | 75(phase-to-phase, phase-to-earth) | ||||||||
4 | |
A | 630 | 630 | 1250 | 1600 | |||
| 1250 | 1250 | 1600 | 2000 | ||||||
| 2000 | 2500 | ||||||||
| 2500 | 3150 | ||||||||
| 4000 | |||||||||
| 5 | Rated short-circuit breaking current |
KA | 20 | 25 | 31.5 | 40 | |||
| 6 | Rated short-time withstand current | 20 | 25 | 31.5 | 40 | ||||
| 7 | Rated short-circuit marking current | 50 | 63 | 80 | 100 | ||||
| 8 | Rated peak withstand current | 50 | 63 | 80 | 100 | ||||
| 9 | Rated duration of short-circuit | s | 4 | ||||||
| 10 | Rated operating sequence | O-0.3s-O/C-180s-O/C | |||||||
| 11 | Breaking times of rated short-circuit current | Times | 30/20 times(40KA) | ||||||
| 12 | Mechanical endurance | Ops | 20000 | ||||||
| 13 | Rated single capacitor bank breaking current |
A | 630 | ||||||
| 14 | Rated back-to-back capacitor bank breaking current | 400 | |||||||
| 15 | Double-earth fault breaking current | 27.4 | |||||||
| 16 | Allowable maximum contact erosion |
mm | 3 | ||||||
| 17 | Clearance between open contacts | 10±1 | |||||||
| 18 | Over stroke | 3.5±0.5 | |||||||
| 19 | Non-simultaneity of 3-phase opening and closing | ms
| ≤2 | ||||||
| 20 | Bounce duration of contact closing | ≤2 | |||||||
| 21 | Average breaking speed (instant breaking 6mm) | m/s
| 1.1±0.2 | ||||||
| 22 | Average making speed | 0.8±0.2 | |||||||
| 23 | Making time | ms
| ≤100 | ||||||
| 24 | Breaking time | ≤50 | |||||||
25 | |
μ Ω | 630A | ≤50 | |||||
| 1250A | ≤45 | ||||||||
| 1600A~2000A | ≤35 | ||||||||
| ≥2500A | ≤25 | ||||||||
| 26 | Contact breaking bounce amplitude | mm | ≤2 | ||||||
27 | Rated operating voltage | Rated operating voltage(V)AC/DC |
V | 24* | 110 | 220 | |||
| Scope of normal operation voltage | Opening:65%-120% rated voltage, in case the voltage is lower than 30% rated voltage, opening operation is not allowed | ||||||||
| 28 | Rated voltage of energy storage motor | V | AC110/220,DC110/220 | ||||||
| 29 | Energy storage time | S | ≤15 | ||||||
![]()