Large Image :  SF6 GIS HXGN15-12 Gas Insulated RMU Switchgear 12KV

Product Details:
Place of Origin: China
Brand Name: Knkong
Certification: IEC ISO
Model Number: SF6 GIS HXGN15-12
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Standard export packaging
Delivery Time: 30 days
Payment Terms: L/C, T/T
Supply Ability: 100 Unit per month

SF6 GIS HXGN15-12 Gas Insulated RMU Switchgear 12KV

Description
Rating Voltage: 12KV Rating Current: 630-1250A
Rating Frequency: 50/60Hz Standards: GB ISO IEC
OEM/ODM: Please Your CDA Drawings Original: China
High Light:

Gas Insulated RMU Switchgear

,

SF6 GIS HXGN15-12 RMU Switchgear

,

RMU Switchgear 12KV

GB ISO 36KV Gas Insulated Switchgear Medium Voltage Ring Main Unit

 

SF6 RMU HXGN15 Series 12KV GIS GB ISO IEC

Product Introduction

 

General

This type of  RMU switchgear using SF6 as an arc extinguishing medium with double open contacts, 3 working-position and rotating contact which placed in an epoxy resin shell of a reinforced structure. Each gas tank must be passed helium-leak detection before being filled with 0.045Mpa SF6 (Inspect any leakage to ensure can be installed vertically or horizontally). 

 

Service environment

  • Air temperature: -35℃~+40℃
  • Humidity: Monthly average 95%; Daily average 90%.
  • Altitude:≤ 1000m (Up to 5000 m can be custom)
  • Ambient air not apparently polluted by corrosive and flammable gas, vapor, etc.
  • No frequent violent shake

 

Technical Data

No. Item Unit Parameter
1 Rated voltage kV 12 24 36
2 Rated frequency Hz 50/60
3 Rated current A 630(1250*)
4

1min Power frequency

withstand voltage

wet kV 38 50 70
dry kV 48 60 85
5 Lightning impulse withstand voltage kV 75 125/150 170
6 Rated short circuit breaking current (peak) kA 80 63 63
7 Rated active load and close circuit breaking current A 63 50 50
8 Rated transferring current A 1700 1200 1200
9 Rated short circuit making a current (peak) kA 80 63 63
10 Rated cable(line) charging breaking current A

50 and 10

50/10

11 Cable charge breaking current in earthing fault A 20 20 20
12 Rated withstand current (peak) kA 80 63 63
13 Short-time withstand current (2s) kA 25 20 20
14 Mechanism life times 5000 2000 2000

Note: For short circuit breaking and the peak current is based on Fuse plus combination

 

Optional components:
Electric operating-AC 220/110V; DC 24/48/110/220V
Auxiliary contact 5 NO 5 NC
Full set of fuse
FTU communication interface

 