Product Details:
|
Voltage: | 12KV | Current: | 630A 1250A |
---|---|---|---|
Frequency: | 50Hz | Standards: | CCC,ISO9001,CE, CB,IEC60898 |
OEM/ODM: | Available | Manufactory: | KNKONG |
High Light: | 12kv VCB Circuit Breaker,ZW32 VCB Circuit Breaker,OEM 12kv VCB |
Product Introduction
The ZW32-12 type double isolation double outlet outdoor high voltage vacuum circuit breaker is a control and maintenance equipment in the AC three-phase high voltage power distribution network with a rated voltage of 12KV and 50Hz. The recloser is an intelligent device that can be used in conjunction with the sectionalizer to realize power distribution automation without relying on another control system. The recloser is composed of a circuit breaker (and its operating mechanism), a controller, and a control power supply. In addition to being able to open and close normal and faulty high-voltage lines like the circuit breaker, it can also press The preset number of times of automatic reclosing is performed for multiple times so that the sectioner will act to isolate the faulty line during the reclosing interval, and the intact line will restore power; if the recloser fails for many times, the recloser will be closed and locked. At this time, At the other end of the ring network (or "hand in hand" network), the principle is that the recloser, which is closed and locked, is automatically closed when the lock is released, and the power supply can be restored immediately if the line is intact. Power grid automation can limit the scope of power outage to the smallest extent after a fault occurs, which has high social and economic benefits. The stupid product has the "four remote" remote communication function, which can realize optical fiber, microwave, carrier, radio and GSM.
Features
Normal service condition
Altitude |
≤1000m |
|
Ambient temperature |
Max |
+40℃ |
Min |
-15℃ |
|
Ambient humidity: Maximum average humidity |
24 hour ≤95% |
|
1 month ≤90% |
||
Maximum water vapor pressure |
24 hours ≤2.2kpa |
|
1 month ≤1.8kpa |
The ambient air has no obvious pollution of dust smoke, corrosive or combustible gases, steams or smog
12kv Outdoor VCB Technical Parameters
No. | Items | Unit | Parameter | |
1 | Rated voltage | KV | 12 | |
2 | Rated current | A | 630 1250 | |
3 | Rated frequency | Hz | 50/60 | |
4 |
1 minute withstand pressure |
Wet |
KV |
34 |
Dry | 42 | |||
To ground | 49 | |||
5 |
Lightning shock withstand current phase, to ground |
KV |
75/85 |
|
6 | Rated short-circuit breaking current |
KA |
20 25 | |
7 | Rated short-circuit closing current | 50 63 | ||
8 | Rated peak value of withstanding current | 50 63 | ||
9 | 4s short-time withstand current | 20 25 | ||
10 | Rated operating sequence | O-0.3s-CO-180s-CO | ||
11 |
Rated short circuit breaking current breaking times |
times |
30 |
|
12 | Mechanical endurance | 30000 | ||
13 | Permanent magnet control voltage | V | AC/DC 220 | |
14 |
Secondary circuit, 1-minute power frequency withstand voltage |
KV |
2 |
Standerd Drawing
Contact Person: Ken Chan (English)