Home ProductsElectric Power Transformer

ISO IEC GB 10KV/0.4KV 800KVA 3 Phase Power Transformer

Certification
China Knkong Electric Co.,Ltd certification
China Knkong Electric Co.,Ltd certification
I'm Online Chat Now

ISO IEC GB 10KV/0.4KV 800KVA 3 Phase Power Transformer

ISO IEC GB 10KV/0.4KV 800KVA 3 Phase Power Transformer
ISO IEC GB 10KV/0.4KV 800KVA 3 Phase Power Transformer

Large Image :  ISO IEC GB 10KV/0.4KV 800KVA 3 Phase Power Transformer

Product Details:
Place of Origin: China
Brand Name: Knkong
Certification: ISO IEC CB
Model Number: S11
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: USD 1000-3000
Packaging Details: Standard export packaging
Delivery Time: 15 days
Payment Terms: L/C, T/T
Supply Ability: 100 Unit per month

ISO IEC GB 10KV/0.4KV 800KVA 3 Phase Power Transformer

Description
Rating Voltage: 10KV/0.4KV Rating Capacity: 30-1600KVA
Rating Frequency: 50/60Hz Standards: ISO IEC GB
Material: Copper/Aluminum Manufactory: KNKONG
High Light:

800KVA 3 Phase Power Transformer

,

10KV/0.4KV 3 Phase Power Transformer

,

three phase power transformer

10/0.4KV 3-phases oil type power transformer 30-2500KVA ISO IEC GB

Product Introduction

The oil-immersed transformer is one of the important pieces of equipment in the power supply and distribution system of industrial and mining enterprises and civil buildings. It reduces the 10(6)kV or 35kV network voltage to the 230/400V bus voltage used by the user. This type of product is suitable for AC 50 (60) Hz, three-phase maximum rated capacity 2500kVA (single-phase maximum rated capacity 833kVA, single-phase transformer is generally not recommended), can be used indoors (outdoor), when the capacity is 315kVA and below Can be installed on a pole, the ambient temperature is not higher than 40℃, not lower than -25℃, the highest daily average temperature is 30℃, the highest annual average temperature is 20℃, the relative humidity does not exceed 90% (ambient temperature 25℃), altitude No more than 1000m. If it is inconsistent with the above conditions of use, appropriate quota adjustments should be made in accordance with the relevant provisions of GB6450-86.

 

Features
1. The transformer iron core greatly reduces the no-load loss and no-load current, and the iron core is bound to ensure the tightness of the iron core and reduce noise.
2. The high and low voltage windings are made of oxygen-free copper, and the low voltage windings of 500kVA and below adopt a double-layer cylindrical structure. 630kVA and above adopt double-spiral or quad-spiral structure, and high-voltage winding adopts multi-layer cylindrical structure.
3. The transformer connection group uses Dyn11 to reduce the impact of harmonics on the power grid and improve the quality of power supply.
4. The transformer is a fully sealed structure, which prolongs the service life, does not need to hang the core and is free of maintenance.
5. The measured noise value is lower than the standard.
After this series of transformers are transported normally, the relevant parts can be installed without core checking, and the acceptance test can be carried out, and they can be put into operation after being qualified.

 

Product Standards

GB1094.1-2013
GB1094.2-2013
GB1094.3-2003
GB1094.5-2008
GB/T1094.10-2003
GB/T25446-2010

 

Performance characteristics
a. The low-voltage windings of oil-immersed transformers generally adopt a cylindrical structure with copper foil around the shaft, except for the small-capacity copper wires; the high-voltage winding adopts a multi-layer cylindrical structure to balance the ampere-turn distribution of the winding and cause leakage. Small, high mechanical strength, strong short-circuit resistance.
b. The iron core and the winding are each adopted with fastening measures. The fastening parts such as the height of the device and the low-voltage lead are equipped with self-locking lock nuts, and the non-suspending structure is adopted to withstand the shock of transportation.
c. The coil and iron core are vacuum dried, and the transformer oil is vacuum filtered and oiled to minimize the moisture inside the transformer.
d. The oil tank adopts corrugated sheet, which has a breathing function to compensate for the volume change of the oil caused by temperature changes, so this product does not have an oil conservator, which obviously reduces the height of the transformer.
e. Because the corrugated sheet replaces the oil conservator, the transformer oil is isolated from the outside world, which effectively prevents the entry of oxygen and moisture, which leads to a decrease in insulation performance.
f. According to the above five points of performance, it is ensured that the oil-immersed transformer does not need to be changed during normal operation, which greatly reduces the maintenance cost of the transformer and prolongs the service life of the transformer.

 

10KV S11 Oil Transformer main technical data

Rated Capacity
(KVA)
High
voltage
(KV)
Tapping
Range
Low
voltage
(KV)
Frequency
(Hz)
Connection
Symbol
No-load loss
(W)
load loss
(W)
No-load Current
(%)
Noise level
(dB)
Short-circuit
impedance (%)
Gauge
A x B
(mm x mm)
Dimensions
L*W*H (mm)
Weight (KG)
30 6
6.3
6.6
10
10.5
11
±5%
±2X 2. 5%
0.4 50
  1. yn11
  2. Y, ynO
100 630 2.3 44 4 400 770X545X890 260
50 130 910 2.0 44 400 790X560X920 320
80 180 1310 1.9 48 400 850X635X980 420
100 200 1580 1.8 48 550 865X685X990 470
160 280 2310 1.6 49 550 1120X740X1050 610
200 340 2730 1.5 51 550 1235X825X1080 750
250 400 3200 1.4 51 550 1275X860X1100 850
315 480 3830 1.4 53 550 1300X870X1170 960
400 570 4520 1.3 53 660 1395X960X1190 1160
500 680 5410 1.2 54 660 1530X1080X1230 1340
630 810 6200 1.1 54 4.5 660 1660X1180X1300 1660
800 980 7500 1.0 57 820 1740X1255X1400 2100
1000 1150 10300 1.0 57 820 1780X1320X1490 2400
1250 1360 12000 0.9 59 820 1855X1345X1580 2850
1600 1640 14500 0.8 59 820 1960X1415X1700 3430

 

10KV-S13/14 Oil Transformer main technical data

Rated Capacity
(KVA)
High
voltage
(KV)
Tapping
Range
Low
voltage
(KV)
Frequency
(Hz)
Connection
Symbol
No-load loss
(W)
load loss
(W)
No-load Current
(%)
Noise level
(dB)
Short-circuit
impedance (%)
Gauge
A x B
(mm x mm)

Dimensions

L*W*H (mm)

Weight (KG)
S13 S14 S13 S14
30

6

6.3

6.6

10

10.5

11

±5%

±2X 2.5%

0.4 50 D, yn11 Y. ynO 80 80 630/600 505/480 1.4 50 4 400X40C 1005X670X960 280
50 100 100 910/870 730/695 1.2 50 400 X 40C 1005X670X990 390
80 130 130 1310/1250 1050/1000 0.97 52 400X40C 1060 X 715X1040 495
100 150 150 1580/1500 1265/1200 0.97 52 550X55C 1075X735X1060 600
125 170 170 1890/1800 1510/1440 0.84 54 550X55C 1110X750X1100 690
160 200 200 2310/2200 1850/1760 0.84 54 550X55C 1140X780X1130 780
200 240 240 2730/2600 2185/2080 0.74 56 550X55C 1210X815X1150 908
250 290 290 3200/305 2560/2440 0.64 56 550X55C 1290X885X1190 1043
315 340 340 3830/3650 3065/2920 0.64 58 550X55C 1300X880X1230 1190
400 410 410 4520/4300 3615/3440 0.54 58 660 X 66C 1410X975X1300 1430
500 480 480 5410/5150 4330/4120 0.54 60 660X66C 1465 X 980X1390 1648
630 570 570 6200 4960 0.54 60 4.5 660X66C 1560X1050X1410 2027
800 700 700 7500 6000 0.48 62 820X82C 1700X1160X1480 2500
1000 830 830 10300 8240 0.42 62 820X82C 1790X1280X1520 2700
1250 970 970 12000 9600 0.36 65 820X82C 1890X1360X1600 3280
1600 1170 1170 14500 11600 0.36 69 820X82C 1970X1430X1700

3500