Home ProductsGas Insulated Switchgear

Electrical Fully Insulated Sf6 Gis Switchgear 630A Mechanical

Certification
China Knkong Electric Co.,Ltd certification
China Knkong Electric Co.,Ltd certification
I'm Online Chat Now

Electrical Fully Insulated Sf6 Gis Switchgear 630A Mechanical

Electrical Fully Insulated Sf6 Gis Switchgear 630A Mechanical
Electrical Fully Insulated Sf6 Gis Switchgear 630A Mechanical

Large Image :  Electrical Fully Insulated Sf6 Gis Switchgear 630A Mechanical

Product Details:
Place of Origin: China
Brand Name: Knkong
Certification: IEC ISO GB
Model Number: SF6 GIS HXGN15-12 Circuit breaker unit
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Standard export packaging
Delivery Time: 30 days
Payment Terms: L/C, T/T
Supply Ability: 100 Unit per month

Electrical Fully Insulated Sf6 Gis Switchgear 630A Mechanical

Description
Running Voltage: Max 36KV Running Current: 630-1250A
Running Frequency: 50/60Hz Type: Fully Insulated
Original: China Manufactory: KNKONG
High Light:

Fully Insulated Sf6 Gis Switchgear

,

Electrical Sf6 Gis Switchgear

,

Sf6 Gis Switchgear 630A

SF6 RMU GIS electrical equipment fully insulated type

Voltage: max 33KV

Current: 630-1250A

Type: SF6 fully insulated

 

General

The VCB unit in the entire group of equipment is also called a vacuum V-type unit, which is used to break short-circuit current, and its circuit breaker is connected in series with a two-position isolating switch.
When the isolating switch is in the off position, the interlock grounding switch will close to ground the cable bushing.
The operating mechanism between it and the isolating switch and the operating mechanism between the isolating switch and the grounding switch are mechanical.

 

Service environment

  • Air temperature: -35℃~+40℃
  • Humidity: Monthly average 95%; Daily average 90%.
  • Altitude:≤ 1000m (Up to 5000 m can be custom)
  • Ambient air is not apparently polluted by corrosive and flammable gas, vapor, etc.
  • No frequent violent shake

 

Technical Data

No. Item Unit Parameter
1 Rated voltage kV 12 24 36
2 Rated frequency Hz 50/60
3 Rated current A 630(1250*)
4

1min Power frequency

withstand voltage

wet kV 38 50 70
dry kV 48 60 85
5 Lightning impulse withstand voltage kV 75 125/150 170
6 Rated short circuit breaking current (peak) kA 80 63 63
7 Rated active load and close circuit breaking current A 63 50 50
8 Rated transferring current A 1700 1200 1200
9 Rated short circuit making a current (peak) kA 80 63 63
10 Rated cable(line) charging breaking current A

50 and 10

50/10

11 Cable charge breaking current in earthing fault A 20 20 20
12 Rated withstand current (peak) kA 80 63 63
13 Short-time withstand current (2s) kA 25 20 20
14 Mechanism life times 5000 2000 2000

 

 

Electrical Fully Insulated Sf6 Gis Switchgear 630A Mechanical 0

 

 

Contact Details
Knkong Electric Co.,Ltd

Contact Person: Antonio

Tel: +8613607680651

Send your inquiry directly to us (0 / 3000)