Product Details:
|
Working Voltage: | 12-24KV | Working Current: | Max 2000A |
---|---|---|---|
Breaking Current: | Max 25KA | Type: | Fixed |
Phase Spacing: | 205-310 | Brand: | KNKONG-ELECTRIC |
High Light: | 25KA Breaking VCB Circuit Breaker,Fixed VCB Circuit Breaker,205mm Phase Spacing VCB Circuit Breaker |
205mm Phase spacing 25KA breaking fixed vacuum circuit breaker VS1
Voltage: 12-24KV
Current: max 2000A
Breaking current: max 25KA
Type: Fixed
Phase spacing: 205-310mm
Product overview
The VS1 circuit breaker is independently developed by Knkong and adopts a modular mechanism. Compared with the traditional VS1 circuit breaker, it is easy to install, maintain, test and operate. It has higher operational stability, higher safety and longer service life. This product can meet the application needs of customers in 12kV and 24kV power transmission and distribution systems and is widely used to replace traditional European brands.
VS1-Series circuit breaker features high stability and high reliability
In terms of braking mechanisms, VS1 series vacuum circuit breakers have optimized transmission components. The modularization of the spring mechanism makes it easy to maintain, has short maintenance time for power failure, and strong versatility of parts. The colleague's vacuum interrupter has better compatibility and improved performance.
Normal service condition
Altitude | ≤1000m | |
Ambient temperature | Max | +40℃ |
Min | -15℃ | |
Ambient humidity: Maximum average humidity |
24 hours ≤95% | |
1 month ≤90% | ||
Maximum water vapor pressure | 24 hours ≤2.2kpa | |
1 month ≤1.8kpa |
Technical Parameters
No. | Item | Unit | Parameter | ||||||
1 | Rated voltage | KV | 12 | ||||||
2 | Rated frequency | Hz | 50/60 | ||||||
3 |
Rated insulation level |
1min power frequency withstand voltage(r. m. s) |
KV |
42(phase-to-phase, phase-to-earth) 48(across the isolating distance) |
|||||
Lighting impulse withstand voltage (peak) |
75(phase-to-phase, phase-to-earth) 85(across the isolating distance) |
||||||||
4 |
Rated current |
A |
630 | 630 | 1250 | 1600 | |||
1250 | 1250 | 1600 | 2000 | ||||||
2000 | 2500 | ||||||||
2500 | 3150 | ||||||||
4000 | |||||||||
5 | Rated short-circuit breaking current |
KA |
20 | 25 | 31.5 | 40 | |||
6 | Rated short-time withstand current | 20 | 25 | 31.5 | 40 | ||||
7 | Rated short-circuit marking current | 50 | 63 | 80 | 100 | ||||
8 | Rated peak withstand current | 50 | 63 | 80 | 100 | ||||
9 | Rated duration of short-circuit | s | 4 | ||||||
10 | Rated operating sequence | O-0.3s-O/C-180s-O/C | |||||||
11 | Breaking times of rated short-circuit current | Times | 30/20 times(40KA) | ||||||
12 | Mechanical endurance | Ops | 20000 | ||||||
13 | Rated single capacitor bank breaking current |
A |
630 | ||||||
14 | Rated back-to-back capacitor bank breaking current | 400 | |||||||
15 | Double-earth fault breaking current | 27.4 | |||||||
16 | Allowable maximum contact erosion |
mm |
3 | ||||||
17 | Clearance between open contacts | 10±1 | |||||||
18 | Over stroke | 3.5±0.5 | |||||||
19 | Non-simultaneity of 3-phase opening and closing |
ms
|
≤2 | ||||||
20 | Bounce duration of contact closing | ≤2 | |||||||
21 | Average breaking speed (instant breaking 6mm) |
m/s
|
1.1±0.2 | ||||||
22 | Average making speed | 0.8±0.2 | |||||||
23 | Making time |
ms
|
≤100 | ||||||
24 | Breaking time | ≤50 | |||||||
25 |
Resistance of each phase main circuit |
μ Ω |
630A | ≤50 | |||||
1250A | ≤45 | ||||||||
1600A~2000A | ≤35 | ||||||||
≥2500A | ≤25 | ||||||||
26 | Contact breaking bounce amplitude | mm | ≤2 | ||||||
27 |
Rated operating voltage | Rated operating voltage(V)AC/DC |
V |
24* | 110 | 220 | |||
Scope of normal operation voltage | Opening:65%-120% rated voltage, in case the voltage is lower than 30% rated voltage, opening operation is not allowed | ||||||||
28 | Rated voltage of energy storage motor | V | AC110/220, DC110/220 | ||||||
29 | Energy storage time | S | ≤15 |