Home ProductsGas Insulated Switchgear

12KV RMU SF6 Load Switch Gas Insulated Switchgear HXGN15

Certification
China Knkong Electric Co.,Ltd certification
China Knkong Electric Co.,Ltd certification
I'm Online Chat Now

12KV RMU SF6 Load Switch Gas Insulated Switchgear HXGN15

12KV RMU SF6 Load Switch Gas Insulated Switchgear HXGN15
12KV RMU SF6 Load Switch Gas Insulated Switchgear HXGN15

Large Image :  12KV RMU SF6 Load Switch Gas Insulated Switchgear HXGN15

Product Details:
Place of Origin: China
Brand Name: Knkong
Certification: IEC ISO
Model Number: SF6 GIS HXGN15-12 load switch unit
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Standard export packaging
Delivery Time: 30 days
Payment Terms: L/C, T/T
Supply Ability: 100 Unit per month

12KV RMU SF6 Load Switch Gas Insulated Switchgear HXGN15

Description
Rated Voltage: 12KV Rated Current: 630-1250A
Rated Frequency: 50/60Hz Type: Load Switch Unit
OEM/ODM: Please Share Your CDA Drawings Original: China
High Light:

Load Switch Gas Insulated Switchgear

,

12KV RMU Gas Insulated Switchgear

,

SF6 Gas Insulated Switchgear

SF6 RMU HXGN15 Load Switch Module 12KV GIS GB ISO IEC

 

Product Introduction

 

General

The load switch for the power supply cabinet is generally called C module, which is generally used in high-voltage three-phase five-wire cabinets.

Load switch unit which called C-unit included bus-bar, three-station load/earth switch, three-station single spring operating mechanism, there are two independent load switch and ground, switch operation hole, load switch and earthing switch position indication, indicates the kiln voltage indicator of the casing, etc.

 

 

Service environment

  • Air temperature: -35℃~+40℃
  • Humidity: Monthly average 95%; Daily average 90%.
  • Altitude:≤ 1000m (Up to 5000 m can be custom)
  • Ambient air not apparently polluted by corrosive and flammable gas, vapor, etc.
  • No frequent violent shake

 

Technical Data

No. Item Unit Parameter
1 Rated voltage kV 12 24 36
2 Rated frequency Hz 50/60
3 Rated current A 630(1250*)
4

1min Power frequency

withstand voltage

wet kV 38 50 70
dry kV 48 60 85
5 Lightning impulse withstand voltage kV 75 125/150 170
6 Rated short circuit breaking current (peak) kA 80 63 63
7 Rated active load and close circuit breaking current A 63 50 50
8 Rated transferring current A 1700 1200 1200
9 Rated short circuit making a current (peak) kA 80 63 63
10 Rated cable(line) charging breaking current A

50 and 10

50/10

11 Cable charge breaking current in earthing fault A 20 20 20
12 Rated withstand current (peak) kA 80 63 63
13 Short-time withstand current (2s) kA 25 20 20
14 Mechanism life times 5000 2000 2000

Note: For short circuit breaking and the peak current is based on Fuse plus combination

 

Optional components:
Electric operating-AC 220/110V; DC 24/48/110/220V
Auxiliary contact 5 NO 5 NC
Full set of fuse
FTU communication interface

 

12KV RMU SF6 Load Switch Gas Insulated Switchgear HXGN15 0

 

 