12KV 630A Gas Insulated Switchgear RMU Ring Main Unit

12KV 630A Gas Insulated Switchgear RMU Ring Main Unit
12KV 630A Gas Insulated Switchgear RMU Ring Main Unit

Large Image :  12KV 630A Gas Insulated Switchgear RMU Ring Main Unit

Product Details:
Place of Origin: China
Brand Name: Knkong
Certification: IEC ISO
Model Number: SF6 GIS HXGN15-12
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Standard export packaging
Delivery Time: 30 days
Payment Terms: L/C, T/T
Supply Ability: 100 Unit per month

12KV 630A Gas Insulated Switchgear RMU Ring Main Unit

Description
Rating Voltage: 12KV Rating Current: 630A
Rating Frequency: 50/60Hz Standards: GB ISO IEC
OEM/ODM: Inquiry By Email Manufactory: KNKONG
High Light:

12KV 630A Gas Insulated Switchgear

,

RMU Ring Main Unit

,

Arc Extinguishing Ring Main Unit

GB ISO 36KV Gas Insulated Switchgear Medium Voltage Ring Main Unit

Product Introduction

 

General

This RMU switchgear using SF6 as an arc extinguishing medium with double open contacts, 3 working-position and rotating contact which placed in an epoxy resin shell of a reinforced structure. Each gas box must pass helium leak detection before being filled with 0.045Mpa SF6 (Inspect any leakage to ensure can be installed vertically or horizontally). The classic installation is "horizontal", that is, install steel partitions between the cable compartment and the busbar compartment. That makes the interval between the busbar and the cable joint the most stringent safety requirements.

 

Standard

  • ISO 780-1997,MOD
  • IEC 62271-102:2002,MOD
  • IEC 60265-1:1998,MOD
  • IEC 60298:1990
  • IEC 60529:1989
  • IEC 507:1991
  • IEC 60694:1996
  • IEC 60420:1990

 

Technical Data

No. Item Unit Parameter
1 Rated voltage kV 12 24 36
2 Rated frequency Hz 50/60
3 Rated current A 630(1250*)
4

1min Power frequency

withstand voltage

wet kV 38 50 70
dry kV 48 60 85
5 Lightning impulse withstand voltage kV 75 125/150 170
6 Rated short circuit breaking current (peak) kA 80 63 63
7 Rated active load and close circuit breaking current A 63 50 50
8 Rated transferring current A 1700 1200 1200
9 Rated short circuit making a current (peak) kA 80 63 63
10 Rated cable(line) charging breaking current A

50 and 10

50/10

11 Cable charge breaking current in earthing fault A 20 20 20
12 Rated withstand current (peak) kA 80 63 63
13 Short-time withstand current (2s) kA 25 20 20
14 Mechanism life times 5000 2000 2000

Note: For short circuit breaking and the peak current is based on Fuse plus combination