Product Details:
|
| Rating Voltage: | 6-35KV | Neutral Grounding: | Various |
|---|---|---|---|
| Wiring Type: | Overhead Insulation And Bare Wires 35mm²~240mm² | Main Power: | Line Self-powered (5A Full-function Operation) |
| Acquisition Unit: | ≤80uA | Collection Unit: | ≤0.2VA |
| Highlight: | Gird Electrical Fault Indicator,Intelligent Electrical Fault Indicator,35KV Electrical Fault Indicator |
||
Line Self Powered Intelligent Gird Electrical Fault Indicator 35KV
Product Introduction
Fault indicator refers to a device installed on power lines (overhead lines, cables and busbars) to indicate fault current. Most fault indicators can only distinguish and indicate short-circuit faults by detecting the characteristics of the short-circuit current.
Company
Responsibility: Production research and development MV& LV switch , outdoor&indoor VCB, power distribution terminals (DTU, FTU).
Year of establish: 10th-June-2009
Registered capital:RMB102,000,000 (USD 15,000,000 )
Company License: 91410104689749184A
Manufacturing workshop area:20,000 square meters
Company nature:private enterprise
Number of Employees:180
Senior engineer:20-30
Annual sales volume on 2019:RMB200,000,000 (USD 26,000,000)
Technical Parameter
| Item | Parameter | |
|
Applications |
Voltage | 6~35kV |
| Neutral grounding method | Various grounding methods are available | |
| Wiring type | Overhead insulation and bare wires 35mm²~300mm² | |
|
Collection unit power supply |
Main power | PT/CT |
| Backup power |
Rechargeable battery: Lithium iron phosphate or lead-acid colloid battery is dependent on necessary. All hardware design is compatible for them both. |
|
|
Acquisition unit power supply |
Main power | Line self-powered (5A full-function operation) |
| Backup power | Disposable lithium battery 3.6V, 8.5Ah | |
| Time of duration of the supercapacitor battery> 12 hours | ||
| Static power dissipation | Acquisition unit | ≤40uA |
| Collection unit | ≤0.2VA | |
| Telemetry accuracy | Current |
0~200A,measurement accuracy:±2A 200A~600A,measurement accuracy:±1% |
| Sampling frequency | 4096Hz | |
| Fault detection | Recognizable fault type | Short circuit between phases, various single-phase grounding |
| Instantaneous faults and permanent faults | ||
| Recognition minimum recognition time | 0.2s | |
|
Line status indication |
Indication | Bright LED |
| Flashing time after an outage | >2000h | |
| Fault reset method | Timed automatic reset can be set from 1 to 48 hours | |
| Power-on automatic reset and remote manual reset | ||
|
Local communication |
Frequency band | 430~480MHz |
| Communication medium | Plastic optical fiber | |
| Communication distance | >20m | |
| Mechanical properties | Weight | <2kg |
| Protection level | Acquisition unit IPX7;Collection unit IPX5 | |
| Working environment | Temperature | -40℃~70℃ 10%~ |
| Humidity | 100% | |
| Service life | Operating | >8 years |
| Failure-free time (average) |
MTBF≥70000h |
|