IP40 Modular Power Distribution Switchgear GGD Type Low Voltage

Certification
China Knkong Electric Co.,Ltd certification
China Knkong Electric Co.,Ltd certification
I'm Online Chat Now

IP40 Modular Power Distribution Switchgear GGD Type Low Voltage

IP40 Modular Power Distribution Switchgear GGD Type Low Voltage
IP40 Modular Power Distribution Switchgear GGD Type Low Voltage

Large Image :  IP40 Modular Power Distribution Switchgear GGD Type Low Voltage

Product Details:
Place of Origin: China
Brand Name: KNKONG
Certification: CCC ISO9001 GB7251 IEC439
Model Number: GGD
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Standard export packaging
Delivery Time: 15 working days
Payment Terms: L/C, T/T
Supply Ability: 500 unit per month

IP40 Modular Power Distribution Switchgear GGD Type Low Voltage

Description
Wokring Voltage: Max 380V Working Current: Max 3150A
Using: Power Distribution Standerds: CCC ISO9001 GB7251 IEC439
OEM/ODM: Available Manufactory: KNKONG
High Light:

Modular Power Distribution Switchgear

,

IP40 Power Distribution Switchgear

,

GGD Type Power Distribution Switchgear

380V Power distribution panel GGD switchgear

380V, 50/60 Hz
Modular design, easy assembly
Enclosure: Max. IP40
CCC,ISO9001,GB7251,IEC439
Send us your SLD (Single Line Drawing) or requirements, we design the switchgear plan for you

Inquire

Product Introduction

General

GGD low-voltage switchgear is a GGD type AC low-voltage power distribution cabinet, which is used for fixed wiring low-voltage power distribution cabinets. It is divided into three types: GGD1GGD2GGD3, with different segment current capabilities.
G: AC low-voltage power distribution cabinet
G: Fixed installation and fixed wiring of electrical components
D: Power cabinet
 
 
Conditions of Use
1. The ambient temperature is not higher than +40℃ and not lower than -5℃.
2. When the product is installed and used, the altitude of the place of use should not exceed 2000M.
3. The relative humidity of the surrounding air is not more than 90% (+25℃).
4. The equipment should be installed in a place without severe vibration and impact, and in a place where the electrical components are not corroded.
5. The relative humidity of the surrounding air does not exceed 5% when the maximum temperature is 40 degrees, and a larger relative temperature is allowed at a lower temperature, which should be considered due to
Temperature changes may occasionally produce condensation effects
6. The equipment is installed in a place where there is no severe vibration and impact, and where the electrical components are not corroded
7. When the user has special requirements, it can be resolved through consultation with the manufacturer
 
Install and use
1. The product installation should be carried out according to the installation diagram. The foundation channel steel and bolts should be prepared by the user. When the main busbar is installed, the lap surface should be repaired and leveled, cleaned and coated with neutral petroleum jelly or other measures, and then fixed with bolts.
2. The following items shall be inspected and tested before the product is put into operation after installation.
A Check whether the surface paint of the cabinet body is peeling off, and whether the cabinet is dry and clean
B. Whether the operating mechanism of electrical components is flexible, and there should be no jamming or excessive operating force
C. Whether the on-off of main electrical appliances is reliable and accurate, and whether the on-off of auxiliary contacts is reliable and accurate
D. Whether the indication of the instrument and the change and polarity of the transformer are correct
E. Whether the bus connection is good, whether the insulation support, installation parts and accessories are installed firmly and reliably
Whether the F auxiliary contact meets the requirements, whether the fuse core specification of the fuse is correct, whether the setting value of the relay meets the design requirements, and whether the action is accurate
Whether the contacts of the G circuit meet the requirements of the electrical schematic diagram
H whether the protection circuit system meets the requirements
I Use a 500V megohmmeter to measure the absolute resistance value not less than 1 megohm.
3. Precautions for use:
A This product is not installed against the wall, single-sided (front) operation, double-sided opening doors to repair low-voltage power distribution cabinets. Product maintenance channels and cabinet doors must be qualified professionals to enter or open for operation, inspection and maintenance.
B. Air circuit breaker, after many times of closing and opening, will cause local burns of the main contacts and produce carbon substances, which will increase the contact resistance. The air circuit breaker should be maintained and overhauled according to its operating instructions on a regular basis.

 

 

 