Fixed Type 205 Phase Spacing VCB Circuit Breaker Environmental Protection

Certification
China Knkong Electric Co.,Ltd certification
China Knkong Electric Co.,Ltd certification
I'm Online Chat Now

Fixed Type 205 Phase Spacing VCB Circuit Breaker Environmental Protection

Fixed Type 205 Phase Spacing VCB Circuit Breaker Environmental Protection
Fixed Type 205 Phase Spacing VCB Circuit Breaker Environmental Protection

Large Image :  Fixed Type 205 Phase Spacing VCB Circuit Breaker Environmental Protection

Product Details:
Place of Origin: China
Brand Name: KNKONG
Certification: CB,ISO,IEC
Model Number: VS1-12
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: USD 1000-2000 Each
Packaging Details: Standard export packaging
Delivery Time: 15 working days
Payment Terms: L/C, T/T, Western Union
Supply Ability: 1000 Unit per month

Fixed Type 205 Phase Spacing VCB Circuit Breaker Environmental Protection

Description
Voltage: 12KV Current: 630A
Breaking Current: 25KA Type: Fixed
Original: China Manufactory: KNKONG
High Light:

Fixed Type VCB Circuit Breaker

,

25KA Spacing VCB Circuit Breaker

,

12KV Spacing VCB Circuit Breaker

VS1-12 fixed type 205 phase spacing Vacuum Circuit Breaker 12KV 630A

Voltage: 12KV

Current: 630A

Breaking current: 20KA

Type: Fixed

 

 

Product overview

VS1-Series circuit breakers are complete independently developed by Knkong based on the advanced design concept; it adopts a modularized mechanism, which is easy for installation, maintenance, testing, and operation. As compared with conventional VS1 circuit breaker. it features higher operation stability, higher safety, and extended service life. The product can satisfy customers demand application in 12kv and 24kV power transmission and distribution systems, which is extensively applied in such industries as power, energy, petrochemical engineering, metallurgy, manufacture, traffic, building, and environmental protection as well as large-scale enterprises and national key projects

 

 

Technical Parameters

No. Item Unit Parameter
1 Rated voltage KV 12
2 Rated frequency Hz 50/60
3

 

Rated insulation level

1min power frequency withstand voltage(r. m. s)

 

KV

42(phase-to-phase, phase-to-earth)

48(across the isolating distance)

Lighting impulse withstand voltage (peak)

75(phase-to-phase, phase-to-earth)

85(across the isolating distance)

 

 

4

 

 

Rated current

 

 

A

630 630 1250 1600
1250 1250 1600 2000
    2000 2500
    2500 3150
      4000
5 Rated short-circuit breaking current

 

KA

20 25 31.5 40
6 Rated short-time withstand current 20 25 31.5 40
7 Rated short-circuit marking current 50 63 80 100
8 Rated peak withstand current 50 63 80 100
9 Rated duration of short-circuit     s 4
10 Rated operating sequence   O-0.3s-O/C-180s-O/C
11 Breaking times of rated short-circuit current Times 30/20 times(40KA)
12 Mechanical endurance Ops 20000
13 Rated single capacitor bank breaking current

 

A

630
14 Rated back-to-back capacitor bank breaking current 400
15 Double-earth fault breaking current 27.4
16 Allowable maximum contact erosion

 

mm

3
17 Clearance between open contacts 10±1
18 Over stroke 3.5±0.5
19 Non-simultaneity of 3-phase opening and closing

ms

 

≤2
20 Bounce duration of contact closing ≤2
21 Average breaking speed (instant breaking 6mm)

m/s

 

1.1±0.2
22 Average making speed 0.8±0.2
23 Making time

ms

 

≤100
24 Breaking time ≤50

 

 

25

 

Resistance of each phase main circuit

 

μ Ω

630A ≤50
1250A ≤45
1600A~2000A ≤35
≥2500A ≤25
26 Contact breaking bounce amplitude mm ≤2

 

27

Rated operating voltage Rated operating voltage(V)AC/DC

 

V

24* 110 220
Scope of normal operation voltage Opening:65%-120% rated voltage, in case the voltage is lower than 30% rated voltage, opening operation is not allowed
28 Rated voltage of energy storage motor V AC110/220,DC110/220
29 Energy storage time S ≤15

 

 

Operation safety

The circuit breaker has anti-mis-lock protection and "5 guarantees" interlocking function to avoid misoperation and protect the personal safety of operators to the greatest extent.
Only when the circuit breaker and the grounding switch are in the off position, the circuit breaker cart can roll from the test position to the service position
The circuit breaker can only be closed in the service/test position.
After the circuit breaker is closed, the truck cannot be rolled in or out, only when the circuit breaker is in the open position.
The circuit breaker cannot be rolled out from the service position to the test position in the closed position.
The circuit breaker cannot be closed when pushed in.
When the circuit breaker is closed, if the closing signal is not released in time, the internal anti-trip control circuit will cut off the closing circuit to prevent multiple reclosing (optional).
If electric closing and locking is selected, when the secondary circuit cannot provide power or the power provided cannot satisfy the normal operation of the locking electromagnet (optional), the circuit breaker will not be closed.

 