Product Details:
Place of Origin: China
Brand Name: KNKONG
Certification: CB,ISO,IEC
Model Number: VS1-12
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Standard export packaging
Delivery Time: 15 working days
Payment Terms: L/C, T/T, Western Union
Supply Ability: 1000 Unit per month

VS1-12 VCB 25KA Breaking Fixed Circuit Breaker With 205mm Phase Spacing

Description
Working Voltage: 12KV Or 24KV Working Current: Max 2000A
Breaking Current: 25KA Type: Withdrawable/fixed
Phase Spacing: 205-310mm Brand: KNKONG-ELECTRIC
High Light:

25KA Breaking Fixed Circuit Breaker

,

VCB Fixed Circuit Breaker

,

205mm Phase Spacing Fixed Circuit Breaker

VS1-12 VCB 25KA Breaking fixed indoor circuit breaker with 205mm phase spacing

 

Voltage: 12-24KV

Current: max 2000A

Breaking current: max 25KA

Type: Fixed

Phase spacing: 205-310mm

 

Product overview

VS1 vacuum circuit breaker can perform frequent operations or break short-circuit current multiple times within the working current range; the mechanical life can be up to 30,000 times, and the full-capacity short-circuit current breaking times can be up to 50 times.
VS1 vacuum circuit breakers are suitable for reclosing operation and have extremely high operational reliability and service life.
VS1 vacuum circuit breaker (common type) adopts a vertical insulating cylinder to prevent the influence of various climates; and in terms of maintenance and maintenance, it is usually only necessary to occasionally clean or lubricate the operating mechanism.
The VS1 vacuum circuit breaker (pole type) adopts a solid insulating structure-integrated solid-sealed pole, which realizes maintenance-free.
The installation form of VS1 vacuum circuit breaker in the switch cabinet can be either fixed or withdrawable, and can also be installed on the frame for use

 

Normal service condition

Altitude ≤1000m
Ambient temperature Max +40℃
Min -15℃

Ambient humidity:

Maximum average humidity

24 hours ≤95%
1 month ≤90%
Maximum water vapor pressure 24 hours ≤2.2kpa
1 month ≤1.8kpa

 

 

Technical Parameters

No. Item Unit Parameter
1 Rated voltage KV 12
2 Rated frequency Hz 50/60
3

 

Rated insulation level

1min power frequency withstand voltage(r. m. s)

 

KV

42(phase-to-phase, phase-to-earth)

48(across the isolating distance)

Lighting impulse withstand voltage (peak)

75(phase-to-phase, phase-to-earth)

85(across the isolating distance)

 

 

4

 

 

Rated current

 

 

A

630 630 1250 1600
1250 1250 1600 2000
    2000 2500
    2500 3150
      4000
5 Rated short-circuit breaking current

 

KA

20 25 31.5 40
6 Rated short-time withstand current 20 25 31.5 40
7 Rated short-circuit marking current 50 63 80 100
8 Rated peak withstand current 50 63 80 100
9 Rated duration of short-circuit     s 4
10 Rated operating sequence   O-0.3s-O/C-180s-O/C
11 Breaking times of rated short-circuit current Times 30/20 times(40KA)
12 Mechanical endurance Ops 20000
13 Rated single capacitor bank breaking current

 

A

630
14 Rated back-to-back capacitor bank breaking current 400
15 Double-earth fault breaking current 27.4
16 Allowable maximum contact erosion

 

mm

3
17 Clearance between open contacts 10±1
18 Over stroke 3.5±0.5
19 Non-simultaneity of 3-phase opening and closing

ms

 

≤2
20 Bounce duration of contact closing ≤2
21 Average breaking speed (instant breaking 6mm)

m/s

 

1.1±0.2
22 Average making speed 0.8±0.2
23 Making time

ms

 

≤100
24 Breaking time ≤50

 

 

25

 

Resistance of each phase main circuit

 

μ Ω

630A ≤50
1250A ≤45
1600A~2000A ≤35
≥2500A ≤25
26 Contact breaking bounce amplitude mm ≤2

 

27

Rated operating voltage Rated operating voltage(V)AC/DC

 

V

24* 110 220
Scope of normal operation voltage Opening:65%-120% rated voltage, in case the voltage is lower than 30% rated voltage, opening operation is not allowed
28 Rated voltage of energy storage motor V AC110/220, DC110/220
29 Energy storage time S ≤15

 

 

 

 