Place of Origin: China
Brand Name: KNKONG
Certification: CB,ISO,IEC
Model Number: VS1-12
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Standard export packaging
Delivery Time: 15 working days
Payment Terms: L/C, T/T, Western Union
Supply Ability: 1000 Unit per month

VCB 25KA 1250A Indoor Circuit Breaker With Embedded Pole

Description
Voltage: 12KV 24KV Current: 630A 1250A 1600A 2000A
Breaking Current: 25KA Type: Fixed Type
Standard: GB,IEC,ISO Manufactory: KNKONG-ELECTRIC
High Light:

1250A Indoor Circuit Breaker

,

25KA Indoor Circuit Breaker

,

Embedded Pole 12KV Circuit Breaker

VS1-12KV 1250A indoor VCB 25KA with embedded pole
Voltage: 12KV 24KV
Current: 630A 1250A 2000A
Breaking current: 20KA
Type: Fixed
 
 
Product overview
The VS1-12 series embedded vacuum circuit breaker produced by KNKONG-ELECTRIC is used for 12kV, 24KV three-phase AC 50Hz/60Hz indoor switchgear, it is the best protection and control unit for industrial and mining enterprises and substation equipment. The spring operating mechanism of the circuit breaker is a modular independent frame design, which is often used in KYN28-12 (24) fixed switchgear. These circuit breakers can be either fixed installation or can be used with a trolley when using the withdrawable version.
Technical Parameters

No.ItemUnitParameter
1Rated voltageKV12
2Rated frequencyHz50/60
3

 
Rated insulation level

1min power frequency withstand voltage(r. m. s)

 

KV

42(phase-to-phase, phase-to-earth)
48(across the isolating distance)

Lighting impulse withstand voltage (peak)

75(phase-to-phase, phase-to-earth)
85(across the isolating distance)

 

 

4

 
 
Rated current

 

 

A

63063012501600
1250125016002000
  20002500
  25003150
   4000
5Rated short-circuit breaking current

 

KA

202531.540
6Rated short-time withstand current202531.540
7Rated short-circuit marking current506380100
8Rated peak withstand current506380100
9Rated duration of short-circuit    s4
10Rated operating sequence O-0.3s-O/C-180s-O/C
11Breaking times of rated short-circuit currentTimes30/20 times(40KA)
12Mechanical enduranceOps20000
13Rated single capacitor bank breaking current

 

A

630
14Rated back-to-back capacitor bank breaking current400
15Double-earth fault breaking current27.4
16Allowable maximum contact erosion

 

mm

3
17Clearance between open contacts10±1
18Over stroke3.5±0.5
19Non-simultaneity of 3-phase opening and closing

ms

 

≤2
20Bounce duration of contact closing≤2
21Average breaking speed (instant breaking 6mm)

m/s

 

1.1±0.2
22Average making speed0.8±0.2
23Making time

ms

 

≤100
24Breaking time≤50

 

 

25

 
Resistance of each phase main circuit

 

μ Ω

630A≤50
1250A≤45
1600A~2000A≤35
≥2500A≤25
26Contact breaking bounce amplitudemm≤2

 

27

Rated operating voltageRated operating voltage(V)AC/DC

 

V

24*110220
Scope of normal operation voltageOpening:65%-120% rated voltage, in case the voltage is lower than 30% rated voltage, opening operation is not allowed
28Rated voltage of energy storage motorVAC110/220,DC110/220
29Energy storage timeS≤15

 