12KV 630A MV Gas Insulated Switchgear SF6 Ring Main Unit

Certification
China Knkong Electric Co.,Ltd certification
China Knkong Electric Co.,Ltd certification
I'm Online Chat Now

12KV 630A MV Gas Insulated Switchgear SF6 Ring Main Unit

12KV 630A MV Gas Insulated Switchgear SF6 Ring Main Unit
12KV 630A MV Gas Insulated Switchgear SF6 Ring Main Unit

Large Image :  12KV 630A MV Gas Insulated Switchgear SF6 Ring Main Unit

Product Details:
Place of Origin: China
Brand Name: Knkong
Certification: IEC ISO
Model Number: SF6 GIS HXGN15-12
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Standard export packaging
Delivery Time: 30 days
Payment Terms: L/C, T/T
Supply Ability: 100 Unit per month

12KV 630A MV Gas Insulated Switchgear SF6 Ring Main Unit

Description
Rated Volt: 12KV Rated C: 630A
Rated Hz: 50/60Hz Standards: GB ISO IEC
OEM/ODM: Available Manufactory: KNKONG-ELECTRIC
High Light:

630A MV Gas Insulated Switchgear

,

SF6 Ring Main Unit

,

12KV MV Gas Insulated Switchgear

SF6 Ring main unit 12KV 630A gas-insulated switchgear

 

 

General

The SF6 ring body is an air-insulated or gas-insulated medium-voltage electrical coupling device that uses a load switch as a core component to switch, communicate, and protect the power system and can be freely combined with multiple circuits. Its main circuit core components consist of SF6 load switches or additional circuit breakers and other major auxiliary appliances.

 

Standard

  • ISO 780-1997,MOD
  • IEC 62271-102:2002,MOD
  • IEC 60265-1:1998,MOD
  • IEC 60298:1990
  • IEC 60529:1989
  • IEC 507:1991
  • IEC 60694:1996
  • IEC 60420:1990

 

Technical Data

No. Item Unit Parameter
1 Rated voltage kV 12 24 36
2 Rated frequency Hz 50/60
3 Rated current A 630(1250*)
4

1min Power frequency

withstand voltage

wet kV 38 50 70
dry kV 48 60 85
5 Lightning impulse withstand voltage kV 75 125/150 170
6 Rated short circuit breaking current (peak) kA 80 63 63
7 Rated active load and close circuit breaking current A 63 50 50
8 Rated transferring current A 1700 1200 1200
9 Rated short circuit making a current (peak) kA 80 63 63
10 Rated cable(line) charging breaking current A

50 and 10

50/10

11 Cable charge breaking current in earthing fault A 20 20 20
12 Rated withstand current (peak) kA 80 63 63
13 Short-time withstand current (2s) kA 25 20 20
14 Mechanism life times 5000 2000 2000

Note: For short circuit breaking and the peak current is based on Fuse plus combination

12KV 630A MV Gas Insulated Switchgear SF6 Ring Main Unit 0