Home ProductsGas Insulated Switchgear

IEC VCB SF6 Gas Insulated Rmu Electrical Panel 2000A 36KV

Certification
China Knkong Electric Co.,Ltd certification
China Knkong Electric Co.,Ltd certification
I'm Online Chat Now

IEC VCB SF6 Gas Insulated Rmu Electrical Panel 2000A 36KV

IEC VCB SF6 Gas Insulated Rmu Electrical Panel 2000A 36KV
IEC VCB SF6 Gas Insulated Rmu Electrical Panel 2000A 36KV

Large Image :  IEC VCB SF6 Gas Insulated Rmu Electrical Panel 2000A 36KV

Product Details:
Place of Origin: China
Brand Name: Knkong
Certification: IEC ISO GB
Model Number: SF6 GIS HXGN-40.5
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Standard export packaging
Delivery Time: 30 days
Payment Terms: L/C, T/T
Supply Ability: 100 Unit per month

IEC VCB SF6 Gas Insulated Rmu Electrical Panel 2000A 36KV

Description
Voltage: Max 36KV Current: Max 2000A
Frequency: 50/60Hz Original: China
OEM/ODM: Inquiry By Email Type: Fully Insulated
High Light:

SF6 Gas Insulated Rmu Electrical Panel

,

Rmu Electrical Panel 2000A

,

Rmu Electrical Panel 36KV

VCB Unit in SF6 gas-insulated panel using in RMU

 

Voltage: 36KV

Current: 2000A

Type: SF6 fully insulated

Model: VCB unit

 

General

 
The VCB unit of the equipment in the whole equipment is also called the vacuum V unit, which is used to break the short-circuit current. At the same time, the circuit breaker is connected in series with a two-position isolating switch.
When the isolating switch is in the off position, the interlocking grounding switch is closed to ground the cable bushing.

 

Technical Data

No. Item Unit Parameter
1 Rated voltage kV 12 24 36
2 Rated frequency Hz 50/60
3 Rated current A 630(1250*)
4

1min Power frequency

withstand voltage

wet kV 38 50 70
dry kV 48 60 85
5 Lightning impulse withstand voltage kV 75 125/150 170
6 Rated short circuit breaking current (peak) kA 80 63 63
7 Rated active load and close circuit breaking current A 63 50 50
8 Rated transferring current A 1700 1200 1200
9 Rated short circuit making a current (peak) kA 80 63 63
10 Rated cable(line) charging breaking current A

50 and 10

50/10

11 Cable charge breaking current in earthing fault A 20 20 20
12 Rated withstand current (peak) kA 80 63 63
13 Short-time withstand current (2s) kA 25 20 20
14 Mechanism life times 5000 2000 2000

 

 

IEC VCB SF6 Gas Insulated Rmu Electrical Panel 2000A 36KV 0IEC VCB SF6 Gas Insulated Rmu Electrical Panel 2000A 36KV 1

Contact Details
Knkong Electric Co.,Ltd

Contact Person: Antonio