Home ProductsLow Voltage Switchgear

GCK 660V 4000A Low Voltage Switchgear Metal Clad Type

Certification
China Knkong Electric Co.,Ltd certification
China Knkong Electric Co.,Ltd certification
I'm Online Chat Now

GCK 660V 4000A Low Voltage Switchgear Metal Clad Type

GCK 660V 4000A Low Voltage Switchgear Metal Clad Type
GCK 660V 4000A Low Voltage Switchgear Metal Clad Type

Large Image :  GCK 660V 4000A Low Voltage Switchgear Metal Clad Type

Product Details:
Place of Origin: China
Brand Name: KNKONG
Certification: CCC ISO9001 GB7251 IEC439
Model Number: MNS
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Standard export packaging
Delivery Time: 15 working days
Payment Terms: L/C, T/T
Supply Ability: 500 unit per month

GCK 660V 4000A Low Voltage Switchgear Metal Clad Type

Description
Rating Voltage: Max 660V Rating Current: Max 4000A
Rating Frequency: 50/60Hz Standards: CCC ISO GB IEC
OEM/ODM: Available Manufactory: KNKONG-ELECTRIC
High Light:

4000A Low Voltage Switchgear

,

Metal Clad Type Low Voltage Switchgear

,

660V Low Voltage Switchgear

GCK 660V 4000A low voltage switchgear metal clad type
660V, 50/60 Hz
Modular design, easy assembly
Enclosure: Max. IP40
CCC,ISO9001,GB7251,IEC439
Send us your SLD (Single Line Drawing) or requirements, we design the switchgear plan for you
 

General

The GCK low-voltage switchgear is manufactured by Knkong-electric, and the standard module is comprehensively improved by consulting the Swiss ABB company GCK series low-voltage switchgear. This equipment is used in systems with a working voltage of 660V and below, and is often used as a control device for various power generation, power transmission, power distribution, power transmission, and electrical equipment.

 

Electrical performance
Insulation voltage 660V
Working voltage 380V, 660V
Max working current of main bus 5500A (IP00) 4700A (IP30)
Main busbar short-time (IS) withstand current 100KA (effective value)
Short-time peak current of main busbar 250KA (maximum)
Distribution bus (vertical bus) maximum working current 1000A
Short-term peak current of distribution bus (vertical bus)
Standard type  90KA (maximum)
Enhanced type  130KA (maximum)

 

Technical Data

No. Item Unit Data
1 Rated voltage V 660
2 Rated insulation voltage V 660,1000
3 Rated current A 1250,2000,2500,3200,4000
4 Rated current of drawer accessories A 250,400,630
5 Max Capacity of Motor Kw 320KW
6 Rated peak with standard current KA 105KA,176 KA (0.1S)
7 Insulation: Power frequency withstand voltage V 2500V
8 Protection class   IP40
10 Overall dimension(Width*Depth*Height) MM 600(800,1000)x800(1000)x2200
11 Weight KG 300~1000

 

 

 