Home ProductsMetal Enclosed Switchgear

LV 1000V Solid Insulated Switchgear Withdrawable Switchgear

Certification
China Knkong Electric Co.,Ltd certification
China Knkong Electric Co.,Ltd certification
I'm Online Chat Now

LV 1000V Solid Insulated Switchgear Withdrawable Switchgear

LV 1000V Solid Insulated Switchgear Withdrawable Switchgear
LV 1000V Solid Insulated Switchgear Withdrawable Switchgear

Large Image :  LV 1000V Solid Insulated Switchgear Withdrawable Switchgear

Product Details:
Place of Origin: China
Brand Name: KNKONG
Certification: ISO IEC GB
Model Number: GCK
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: USD 10000-20000 Each
Packaging Details: Standard export packaging
Delivery Time: 15 working days
Payment Terms: L/C, T/T
Supply Ability: 500 unit per month

LV 1000V Solid Insulated Switchgear Withdrawable Switchgear

Description
Insulation Voltage: 660-1000V Working Voltage: 380-660V
Frequency: 50Hz Maximum Current Of Feeder Circuit: 3150A
OEM/ODM: Available Maximum Current Of Drawer Circuit: 3150A
High Light:

1000V Withdrawable Switchgear

,

1000V Solid Insulated Switchgear

,

LV Solid Insulated Switchgear

LV 1000V Solid Insulated Switchgear Withdrawable Switchgear

GCK Type Low Voltage Switchgear 400V 690V LV panels LV switchgear

400/690V, 50/60 HZ ,400~6300A
Modular design, easily assembly
enclosure: Max. IP40
CCC,ISO9001,GB7251,IEC439
Send us your SLD (Single Line Drawing) or requirements, we design the switchgear plan for you
Inquire

Product Introduction

General

GCK should be an improved economical type of MNS. The vertical row has no plastic functional panels. The door is fixed on the frame. After the door is opened, the drawer can be pulled out. G--cabinet structure; C--drawable type; K--control center

 

Working environment

1. The ambient air temperature should not be higher than +40℃, not lower than -5℃, the average temperature within 24h should not be higher than +35℃ if it exceeds, it needs to be derated and run according to the actual situation;
2. Indoor use: the altitude of the place of use shall not exceed 2000m
3. The relative temperature of the surrounding air should not exceed 50% when the temperature is +40℃. A larger relative temperature is allowed at a lower temperature, such as 90% when the temperature is +20℃. It should be considered that condensation may occur accidentally due to temperature changes. The impact of exposure;
4. When the device is installed, the inclination from the vertical plane does not exceed 5°C, and the entire group of cabinets is relatively flat (in accordance with the GBJ232-82 standard);
5. The device should be installed in a place where there is no severe vibration and impact, and where the electrical components are not corroded;
6. If the user has special requirements, it can be resolved through consultation with the manufacturer.
 
Technical Parameters
Rated insulation voltage: AC 660V, AC 1000V
Rated working voltage: AC 380 V, AC 660 V
Rated frequency: 50Hz
Maximum current of feeder circuit: 3150A
Maximum current of drawer circuit: 3150A
Maximum capacity of control motor: 320KW
Horizontal bus peak withstand current (0.1S): 63KA, 105KA, 176KA
Horizontal busbar short-time withstand current (1S): 30 KA, 50 KA, 80 KA, 100 KA
Vertical bus peak withstand current (0.1S): 63 KA, 105 KA
Vertical busbar short-time withstand current (1S): 30 KA, 50 KA
Rated power frequency withstand voltage (1min): 2500V
Secondary power frequency withstand voltage (1min): 2500V
Protection level: IP30, IP40
Dimensions width * depth * height mm: 600 (800, 1000) * 800 (1000) * 2200

Contact Details
Knkong Electric Co.,Ltd

Contact Person: Ken Chan (English)

Tel: 0086 13938551009

Send your inquiry directly to us (0 / 3000)