Home ProductsMedium Voltage Switchgear

AC 50/60Hz ISO GB 1600A General Electric Switchgear 3 Phase

Certification
China Knkong Electric Co.,Ltd certification
China Knkong Electric Co.,Ltd certification
I'm Online Chat Now

AC 50/60Hz ISO GB 1600A General Electric Switchgear 3 Phase

AC 50/60Hz ISO GB 1600A General Electric Switchgear 3 Phase
AC 50/60Hz ISO GB 1600A General Electric Switchgear 3 Phase

Large Image :  AC 50/60Hz ISO GB 1600A General Electric Switchgear 3 Phase

Product Details:
Place of Origin: China
Brand Name: KNKONG
Certification: GB,ISO IEC
Model Number: KYN61-40.5KV
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: USD 6000-15000
Packaging Details: Standard export packaging
Delivery Time: 15 working days
Payment Terms: L/C, T/T
Supply Ability: 50 units/Month

AC 50/60Hz ISO GB 1600A General Electric Switchgear 3 Phase

Description
Rated Voltage: 40.5KV Rated Current: 1600A
Frequency: 50/60Hz Breaking Capacity: 40.5KV
Manufactory: KNKONG OEM/ODM: Inquiry By Email
High Light:

1600A General Electric Switchgear

,

ISO GB General Electric Switchgear

,

40.5KV 3 phase switchgear

40.5KV 1600A AC 50/60Hz KYN61-40.5 IEC ISO GB electrical switchgear

33KV switchgear panel, metal-clad MV switchgear power switchgear panel

KYN61-40.5KV medium voltage switchgear,
Knkong/ABB/Schneider VCB
40.5KV, 3-phase, AC 50/60Hz
Complete ISO IEC standard
For design switchgear SLD plan and layout plan (Single Line Drawing) service please inquiry by email.
Inquire

Product Introduction

Standards
GB3906-2006 "3~35kV AC Metal-enclosed Switchgear"
GB11022-89 "General Technical Requirements for High Voltage Switchgear"
IEC60298 "AC metal-enclosed switchgear and control equipment with rated voltage above 1kV and below 50kV"
DL404-97 "Technical Conditions for Ordering Indoor AC High Voltage Switchgear"
 
Use environment
Normal environmental conditions
1. The upper limit of ambient air temperature: +40℃, the lower limit: -10℃, and the daily average temperature does not exceed 35℃;
2. The altitude does not exceed 1000m;
3. The daily average relative humidity is not more than 95%, and the monthly average is not more than 90%;
4. The earthquake intensity does not exceed 8;
5. The daily average value of water vapor pressure does not exceed 2.2Kpa, and the monthly average value does not exceed 1.8kpa;
6. There is no fire, explosion hazard, severe pollution, chemical corrosion and severe vibration.
Special working conditions
When used under normal environmental conditions beyond the specified, the user and the manufacturer shall negotiate.

 

Technical data

Items Unit Data
Voltage KV 40.5
Frequency Hz 50
Current A 1250,1600,2000
Short-circuit Breaking Current KA 25,31.5
Making Current (Peak) KA 63,80
4s Thermal Stability Current KA 25,31.5
Dynamic Current (Peak) KA 63,80
Insulation Level 1min Power Frequency Withstand Voltage (r.m.s) KV 95
Lightning Impulse Withstand Voltage (Peak) KV 185
1min Power Frequency Voltage Across the open gap (r.m.s) KV 118
Lightning Impulse Withstand Voltage Across the open gap (Peak) KV 215
Enclosure Protection Class  

Enclosure IP4X,

Between Compartments IP2X

Enclosure Dimension (Width*Depth*Height) mm 1400*2800*2600
1600*2800*2600
Type of Circuit Breaker   VCB: ZN85-40.5
SF6 Circuit Breaker

*Note: order switchgear should provide SLD(Single-line diagram) by customer

 

 

Main components characteristics:

 

VS1-40.5 Indoor Vacuum Circuit Breaker

Rating voltage: 40.5kV

Rating current: 630 1250 1600 2000 2500A

Rating short circuit breaking current: 20 25 31.5KA

Mechanical life: no less than 20,000 times

 

VS1-40.5 Technical data

Items Unit Date
voltage

 

KV

40.5
short-time power frequency withstand voltage (1min) 95
lightning impulse withstand voltage (peak) 185
frequency Hz 50/60
current A 1250 1600 2000 2500 4000
short-circuit drop-out current KA 25 31.5
short-time withstand current 25 31.5
short-time continual time s 4
peak withstand current KA 63 80
short-circuit closing current 63 80
single/ back-to-back capacitor bank drop-out current A 630/400
Opening time (rated volt.) ms 35~60
Closing time (rated volt.) 50~100
Mechanical life times 20000
break times for rated short drop-out current s 20
operation voltage V AC110/220 DC110/220
current of power storing motor W 230
Average opening speed m/s 1.6~2.0
Average closing speed 0.5~0.8
operation procedure  

opening-0.3s-closing

opening-180s-closing opening


Knkong Electric 33KV switchgear has served the international market for over the past 10 years.

AC 50/60Hz ISO GB 1600A General Electric Switchgear 3 Phase 0

AC 50/60Hz ISO GB 1600A General Electric Switchgear 3 Phase 1

Contact Details
Knkong Electric Co.,Ltd

Contact Person: Ken Chan (English)

Tel: 0086 13938551009

Send your inquiry directly to us (0 / 3000)