3 Phase Ge Medium Voltage Switchgear 2000A Mv Switchgear Panel

3 Phase Ge Medium Voltage Switchgear 2000A Mv Switchgear Panel
3 Phase Ge Medium Voltage Switchgear 2000A Mv Switchgear Panel

Large Image :  3 Phase Ge Medium Voltage Switchgear 2000A Mv Switchgear Panel

Product Details:
Place of Origin: China
Brand Name: KNKONG
Certification: GB,ISO IEC
Model Number: KYN61A-40.5KV
Payment & Shipping Terms:
Minimum Order Quantity: 1
Price: USD 6000-15000
Packaging Details: Standard export packaging
Delivery Time: 15 working days
Payment Terms: L/C, T/T
Supply Ability: 50 units/Month

3 Phase Ge Medium Voltage Switchgear 2000A Mv Switchgear Panel

Description
Voltage: 40.5KV Current: 2000A
Frequency: 50/60Hz Standards: IEC ISO GB
OEM/ODM: Available Manufactory: KNKONG
High Light:

schneider electric medium voltage switchgear

,

2000A Mv Switchgear Panel

,

Ge Medium Voltage Switchgear

KNKONG-ELECTRIC SWITCHGEAR 40.5KV 2000A KYN61 IEC ISO GB electrical panel

33KV switchgear panel, metal-clad MV switchgear power switchgear panel

KYN61-40.5KV medium voltage switchgear,
Knkong/ABB/Schneider VCB
40.5KV, 3-phase, AC 50/60Hz
Complete ISO IEC standard
For design switchgear SLD plan and layout plan (Single Line Drawing) service please inquiry by email.
Inquire

Product Introduction

KYN61-40.5(Z) refers to the armored removable AC metal-enclosed switchgear (hereinafter referred to as the switchgear) is a three-phase AC 50Hz, rated voltage 40.5kV indoor complete set of power distribution equipment. As power plants, substations and industrial and mining enterprises to receive and distribute electric energy, it can control, protect and detect circuits, and can also be used in places with frequent operations.
 
Scope of application
KYN61-40.5 metal armored central switchgear is designed according to the armored metal enclosed switchgear in GB3906-2006. It is suitable for three-phase AC power system with rated voltage of 40.5kV and rated frequency of 50Hz. It is used to receive and distribute electrical energy and control, protect and detect circuits. In addition to being widely used in general power systems, it can also be used in frequent operations. place.
 

Using environment:

a) Air temperature: -25℃~+40℃

b) Humidity: Monthly humidity 95%; Daily humidity 90%.

c) Altitude no more than 2500m

d) Ambient air not apparently polluted by corrosive and flammable gas, vapor, etc.

e) No frequent violent shake

 

Technical data

Items Unit Data
Voltage KV 40.5
Frequency Hz 50
Current A 1250,1600,2000
Short-circuit Breaking Current KA 25,31.5
Making Current (Peak) KA 63,80
4s Thermal Stability Current KA 25,31.5
Dynamic Current (Peak) KA 63,80
Insulation Level 1min Power Frequency Withstand Voltage (r.m.s) KV 95
Lightning Impulse Withstand Voltage (Peak) KV 185
1min Power Frequency Voltage Across the open gap (r.m.s) KV 118
Lightning Impulse Withstand Voltage Across the open gap (Peak) KV 215
Enclosure Protection Class  

Enclosure IP4X,

Between Compartments IP2X

Enclosure Dimension (Width*Depth*Height) mm 1400*2800*2600
1600*2800*2600
Type of Circuit Breaker   VCB: ZN85-40.5
SF6 Circuit Breaker

*Note: order switchgear should provide SLD(Single-line diagram) by customer

 

 

Main components characteristics:

 

VS1-40.5 Indoor Vacuum Circuit Breaker

Rating voltage: 40.5kV

Rating current: 630 1250 1600 2000 2500A

Rating short circuit breaking current: 20 25 31.5KA

Mechanical life: no less than 20,000 times

 

VS1-40.5 Technical data

Items Unit Date
voltage

 

KV

40.5
short-time power frequency withstand voltage (1min) 95
lightning impulse withstand voltage (peak) 185
frequency Hz 50/60
current A 1250 1600 2000 2500 4000
short-circuit drop-out current KA 25 31.5
short-time withstand current 25 31.5
short-time continual time s 4
peak withstand current KA 63 80
short-circuit closing current 63 80
single/ back-to-back capacitor bank drop-out current A 630/400
Opening time (rated volt.) ms 35~60
Closing time (rated volt.) 50~100
Mechanical life times 20000
break times for rated short drop-out current s 20
operation voltage V AC110/220 DC110/220
current of power storing motor W 230
Average opening speed m/s 1.6~2.0
Average closing speed 0.5~0.8
operation procedure  

opening-0.3s-closing

opening-180s-closing opening


Knkong Electric 33KV switchgear has served the international market for over the past 10 years.

3 Phase Ge Medium Voltage Switchgear 2000A Mv Switchgear Panel 0

3 Phase Ge Medium Voltage Switchgear 2000A Mv Switchgear Panel 1

Contact Details
Knkong Electric Co.,Ltd

Contact Person: Ken Chan (English)

Tel: 0086 13938551009

Send your inquiry directly to us (0 / 3000)