Solid Sealed Pole Vacuum VCB Circuit Breaker 12KV For Transformer Substation

Certification
China Knkong Electric Co.,Ltd certification
China Knkong Electric Co.,Ltd certification
I'm Online Chat Now

Solid Sealed Pole Vacuum VCB Circuit Breaker 12KV For Transformer Substation

Solid Sealed Pole Vacuum VCB Circuit Breaker 12KV For Transformer Substation
Solid Sealed Pole Vacuum VCB Circuit Breaker 12KV For Transformer Substation

Large Image :  Solid Sealed Pole Vacuum VCB Circuit Breaker 12KV For Transformer Substation

Product Details:
Place of Origin: China
Brand Name: KNKONG
Certification: CB,ISO,IEC
Model Number: VS1-12
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Standard export packaging
Delivery Time: 15 working days
Payment Terms: L/C, T/T, Western Union
Supply Ability: 1000 Unit per month

Solid Sealed Pole Vacuum VCB Circuit Breaker 12KV For Transformer Substation

Description
Working Voltage: 12KV-24KV Working Current: Max 2000A
Breaking Current: 25KA Type: Withdrawable/fixed
Original: Zhengzhou, CHINA Manufactory: KNKONG-ELECTRIC
High Light:

Solid Sealed VCB Circuit Breaker 12KV

,

Pole Vacuum VCB Circuit Breaker

,

2000A VCB Circuit Breaker

VCB solid-sealed pole vacuum circuit breaker 2000A 12KV for transformer substation using

Voltage: 12-24KV

Current: Max 2000A

Breaking current: 20KA

Type: withdrawable/Fixed

 

Product overview

VS1-series solid-sealed pole vacuum circuit breaker is suitable for 12kV, 24KV, three-phase alternating current frequency of 50, 60Hz indoor switchgear KYN28-12 (24) central and fixed switchgear operation together. The VS1 vacuum circuit breaker can be fixedly installed or combined with a trolley.

 

Special service condition

The special operating conditions are negotiated in advance by the manufacturer and the user (the manufacturer must consult the user in advance for each special operating condition) such as:
 
-Whether the site altitude exceeds 1000m (or need to order a prototype circuit breaker).
-Allows reducing the dielectric strength of the air.
-Corresponding insulation requirements.
-Situations where the ambient temperature rises.
-Whether the current carrying capacity is reduced.
-Is it necessary to provide additional ventilation for heat dissipation
Other precautions should be negotiated with the manufacturer according to section 2.2 of IEC 62271-1

 

Technical Parameters

No. Item Unit Parameter
1 Rated voltage KV 12
2 Rated frequency Hz 50/60
3

 

Rated insulation level

1min power frequency withstand voltage(r. m. s)

 

KV

42(phase-to-phase, phase-to-earth)

48(across the isolating distance)

Lighting impulse withstand voltage (peak)

75(phase-to-phase, phase-to-earth)

85(across the isolating distance)

 

 

4

 

 

Rated current

 

 

A

630 630 1250 1600
1250 1250 1600 2000
    2000 2500
    2500 3150
      4000
5 Rated short-circuit breaking current

 

KA

20 25 31.5 40
6 Rated short-time withstand current 20 25 31.5 40
7 Rated short-circuit marking current 50 63 80 100
8 Rated peak withstand current 50 63 80 100
9 Rated duration of short-circuit     s 4
10 Rated operating sequence   O-0.3s-O/C-180s-O/C
11 Breaking times of rated short-circuit current Times 30/20 times(40KA)
12 Mechanical endurance Ops 20000
13 Rated single capacitor bank breaking current

 

A

630
14 Rated back-to-back capacitor bank breaking current 400
15 Double-earth fault breaking current 27.4
16 Allowable maximum contact erosion

 

mm

3
17 Clearance between open contacts 10±1
18 Over stroke 3.5±0.5
19 Non-simultaneity of 3-phase opening and closing

ms

 

≤2
20 Bounce duration of contact closing ≤2
21 Average breaking speed (instant breaking 6mm)

m/s

 

1.1±0.2
22 Average making speed 0.8±0.2
23 Making time

ms

 

≤100
24 Breaking time ≤50

 

 

25

 

Resistance of each phase main circuit

 

μ Ω

630A ≤50
1250A ≤45
1600A~2000A ≤35
≥2500A ≤25
26 Contact breaking bounce amplitude mm ≤2

 

27

Rated operating voltage Rated operating voltage(V)AC/DC

 

V

24* 110 220
Scope of normal operation voltage Opening:65%-120% rated voltage, in case the voltage is lower than 30% rated voltage, opening operation is not allowed
28 Rated voltage of energy storage motor V AC110/220,DC110/220
29 Energy storage time S ≤15

 

 

Operation safety

VS1 vacuum circuit breaker has anti-misoperation lockout protection, realizes the "five guarantee" interlock function in the switch cabinet, avoids misoperation, and protects the personal safety of operators to the greatest extent.
Only when the VS1 vacuum circuit breaker and the grounding switch are in the off position at the same time, can the trolley roll from the "detection position" to the "service position".
The VS1 vacuum circuit breaker can only be closed in the "service/test" position.
When the VS1 vacuum circuit breaker is closed, the trolley cannot be moved in or out, only when the circuit breaker is in the off position.
The VS1 vacuum circuit breaker in the closed position cannot be shaken out from the "service position" to the "detection position".
The circuit breaker cannot be closed when pushed in.
When the circuit breaker is closed, if the closing signal is not released in time, the internal anti-trip control circuit will cut off the closing circuit to prevent multiple reclosing (optional).