Home ProductsGas Insulated Switchgear

Fully Insulated 36KV 2000A SF6 RMU Switchgear Fire Extinguishing

Certification
China Knkong Electric Co.,Ltd certification
China Knkong Electric Co.,Ltd certification
I'm Online Chat Now

Fully Insulated 36KV 2000A SF6 RMU Switchgear Fire Extinguishing

Fully Insulated 36KV 2000A SF6 RMU Switchgear Fire Extinguishing
Fully Insulated 36KV 2000A SF6 RMU Switchgear Fire Extinguishing

Large Image :  Fully Insulated 36KV 2000A SF6 RMU Switchgear Fire Extinguishing

Product Details:
Place of Origin: China
Brand Name: Knkong
Certification: IEC ISO GB
Model Number: SF6 GIS HXGN-40.5
Payment & Shipping Terms:
Minimum Order Quantity: 1
Packaging Details: Standard export packaging
Delivery Time: 30 days
Payment Terms: L/C, T/T
Supply Ability: 100 Unit per month

Fully Insulated 36KV 2000A SF6 RMU Switchgear Fire Extinguishing

Description
Normal Voltage: 36KV Normal Current: Max 2000A
Normal Frequency: 50/60Hz Original: China
OEM/ODM: Available Type: Fully Insulated
High Light:

Fully Insulated RMU Switchgear

,

SF6 RMU Switchgear

,

Fire Extinguishing RMU Switchgear

IEC GB fully insulated 36KV 2000A RMU using SF6 switchgear

 

Voltage: 36KV

Current: 2000A

Type: SF6 fully insulated

 

General

The C-unit cable switch described here is equipped with a two-position load switch and an independent grounding switch.
The load switch employs SF6 as the fire extinguishing medium and the load switch meets the corresponding insulation requirements when in the open position.

 

Technical Data

No. Item Unit Parameter
1 Rated voltage kV 12 24 36
2 Rated frequency Hz 50/60
3 Rated current A 630(1250*)
4

1min Power frequency

withstand voltage

wet kV 38 50 70
dry kV 48 60 85
5 Lightning impulse withstand voltage kV 75 125/150 170
6 Rated short circuit breaking current (peak) kA 80 63 63
7 Rated active load and close circuit breaking current A 63 50 50
8 Rated transferring current A 1700 1200 1200
9 Rated short circuit making a current (peak) kA 80 63 63
10 Rated cable(line) charging breaking current A

50 and 10

50/10

11 Cable charge breaking current in earthing fault A 20 20 20
12 Rated withstand current (peak) kA 80 63 63
13 Short-time withstand current (2s) kA 25 20 20
14 Mechanism life times 5000 2000 2000

 

 

 